Heat Exchanger Fouling and Cleaning: Fundamentals and Applications
May 18-22, 2003 - Santa Fe, New Mexico, USA
| Editors: |
Paul Watkinson, University of British Columbia, Canada
Hans Müller-Steinhagen, German Aerospace Centre (DLR) and University of Stuttgart
M. Reza Malayeri, German Aerospace Centre (DLR) |
The articles for these proceedings are peer-reviewed.
|
<Previous article
|
Next article>
|
Development of a Data-Based Method for Performance Monitoring of Heat Exchangers
A. Sawyer, University of Tennessee
A. E. Ruggles, University of Tennessee
B. R. Upadhyaya, University of Tennessee
E. Eryurek, Emerson Process Management
K. Kavaklioglu, Emerson Process Management
J. Miller, Emerson Process Management
ABSTRACT: A multivariate analysis method is developed for processing measurements, and for detecting and isolating faults and monitoring performance degradation in heat exchanger control loops. A heat exchanger inside a typical temperature to flow cascade loop is considered. This system includes a constant speed pump with flow control valves, pressure and temperature measurement. A proportional-integral-differential (PID) controller is used to maintain a temperature set point for the exit flow on one side of the exchanger. A thermal-fluid model for the components in the system is developed.
A Fault Detection and Isolation (FDI) rule-base is formulated from results of simulations performed using these models. Measurements from an installed laboratory heat exchanger control loop are also used.
Faults simulated and induced on the physical heat exchanger loop include tube fouling, sensor drift, fluid leakage, unresponsive valves, plugged process lines, and controller errors. The rule base allows the identification of faults in a heat exchanger control loop given suitable process measurements.
A. Sawyer, A. E. Ruggles, B. R. Upadhyaya, E. Eryurek, K. Kavaklioglu, and J. Miller, "Development of a Data-Based Method for Performance Monitoring of Heat Exchangers" in "Heat Exchanger Fouling and Cleaning: Fundamentals and Applications", Paul Watkinson, Hans Müller-Steinhagen, and M. Reza Malayeri Eds, ECI
Symposium Series, Volume RP1 (2003). http://services.bepress.com/eci/heatexchanger/34
|
|
|
|
 |
|